0086-150-37964-999 furniture@lyeton.com
en ru es
You are here:Home - News - What is the later expansion capacity of compact shelving?

What is the later expansion capacity of compact shelving?

time:July 25, 2025, 6:33 a.m. source:

The later expansion capacity of compact shelving systems depends on several design and installation factors. Here's a breakdown of key considerations:


 

Initial Design Intent

Pre-Planned Expandability: Systems designed for future expansion include:Overbuilt end frames to support additional sections.

Extendable railsbeyond the initial layout.

Modular components (carriages, drives) that can integrate new sections.

Non-Expandable Designs: Some systems are "closed-ended", with fixed terminal sections that block easy extension.

 

Rail System & Layout

Longitudinal Expansion (adding bays to an existing row):

Requires open ends and continuous rails.

Max expansion limited by structural load capacity of floors/walls and drive mechanism

Lateral Expansion (adding new rows):

Demands unused floor space adjacent to the current layout.

Conflicts with walls/columns, HVAC, or electrical systems may restrict growth.

 

Structural & Building Constraints

Floor Load Capacity: Compact shelving + stored materials can exceed 1,500 kg/m². Future expansion must align with building limits.

Ceiling Height: Adding taller units requires vertical clearance.

Aisle Space: New rows need adequate clearance for aisles.

 

Operational Limits

Drive Systems: Manual, mechanical-assist, or electric drives have max bay limits per drive unit Control Systems: Adding sections may require reprogramming central controllers or adding new control points.

 

Manufacturer Compatibility

Component Matching: Mixing brands/series often causes incompatibility.

Obsolete Parts: Legacy systems may lack replacement parts or expandable kits.


 


Best Practices for Future Expansion

Pre-Plan During Installation:

Leave open-ended rails and unused floor space.

Install overbuilt end frames and reinforced flooring.

Document load limits and structural specs.

 

Buffer Capacity:

Reserve 10–20% of floor space for future growth.

Ensure ceiling height accommodates taller units.

 

Consult Professionals:

Conduct a structural engineer’s assessment.

Work with manufacturers to design expandable systems.

 


For maximum flexibility, prioritize modular systems with documented expandability features during procurement. Always validate plans with a structural engineer and manufacturer.

 

 ——YITENG GROUP

Contact Us Now!

In China, We hope to establish business relationship with you in the nearfuture and time will testify that we will be your pleasant and trustworthy cooperation partner. Welcome to contact us and visit our company.

Get a Quote